Fault and solution:
First, the automatic sealing machine clamping nail action is too slow or insufficient clamping stroke: the bolt is loose, the front buckle or the inner piece of the plate wear, at this time you can tighten the bolt, pay attention to the correct position of the front buckle shaft, you can also replace the front buckle or the inner piece of the plate machine, after completing the above action, test its function, if the stroke is too short, then fine-tune the front buckle shaft upward, if the action is slow, then fine-tune the front buckle shaft downward;
Second, gas leakage at the piston rod: the bottom ring of the main body is damaged, and the ring should be replaced at this time;
Third, exhaust air leakage: switch valve ring or switch seat ring damage or piston ring damage, replace the ring;
Fourth, air leakage at the trigger: the switch valve ring or switch seat ring is damaged, replace the ring.